+86 29 8881 0979

November 12, 2025

How to Install Open Ended Waveguides in Indoor Satellites

Align open-ended waveguides via laser tools (±0.1mm accuracy), seal flanges with 0.5mm silicone gel, torque bolts to 5N·m, then test VSWR (<1.2) to ensure indoor satellite signal integrity. Preparation and Planning Ka-band (26.5-40GHz) signals have a loss of approximately 0.3-0.5dB per meter of waveguide. If the waveguide length is extended to 20 meters, the total […]

How to Install Open Ended Waveguides in Indoor Satellites Read More »

What Causes Waveguide Transfer Switch Failures

Waveguide transfer switch failures often stem from mechanical wear (spring fingers fatigue after 10k+ cycles), >10μm particle contamination blocking signal paths, or thermal misalignment—aluminum alloy expands 23μm/°C above 85°C, misaligning flanges for signal loss. Mechanical Structure Failures Over 90% of non-sudden failures originate from the aging or damage of mechanical components (according to 2022 failure

What Causes Waveguide Transfer Switch Failures Read More »

How to Maintain Open Ended Waveguide Probes

Maintain open-ended waveguides by wiping probes with isopropyl alcohol on lint-free cloths, inspecting tips for corrosion/bends, and quarterly calibrating (insertion loss ≤0.5dB) to prevent signal degradation from contaminants or physical damage. Daily Cleaning and Surface Maintenance “Clean” for an open-ended waveguide probe is never just visual “no obvious dust” – dust particles with a diameter

How to Maintain Open Ended Waveguide Probes Read More »

Scroll to Top
Blank Form (#3)