Double-Ridged Waveguide Loop Couplers

Double-ridged waveguide loop couplers provide coaxial RF samples for power monitoring and test access. Published models cover individual bands within 0.84–40 GHz, with 20–60 dB coupling options, 1.15:1 VSWR and 12–15 dB directivity. Specify the WRD interface, sampling direction, main-line power and instrument input limits.

Double-Ridge Waveguide Coupler

Double-Ridged Waveguide Loop Couplers for RF Sampling

Dolph Microwave double-ridged waveguide loop couplers extract a reduced-level RF sample from a WRD waveguide path for power monitoring, system adjustment and test access. The model table lists 13 configurations with individual bands within 0.84–40 GHz, coupling options of 20–60 dB, VSWR of 1.15:1 and directivity of 12–15 dB. Select a complete model row; no single coupler spans the entire family range.

Frequency Coverage 0.84–40.0 GHz
VSWR ≤1.15:1
Coupling Range 20–60 dB
Directivity 12–15 dB
Performance and Construction

Key Features

Choose the waveguide band and sampling direction before specifying the coupling level. DH-840DRWHC30… uses WRD840 over 0.84–2.0 GHz with an N-K output; DH-180DRWHC30… uses WRD180 over 18.0–40.0 GHz with a 2.92-K output. The ordering guide defines K as female. The output connector must match the instrument or sampling cable, as well as the required operating band.

01

Broadband WRD Coverage

The listed WRD models cover different bands between 0.84 and 40 GHz. Match the complete operating band to the selected row, not just its upper frequency.

02

Single or Dual Directional Sampling

Single-directional and dual-directional formats support forward-power, reflected-power or two-direction monitoring.

03

Selectable Coupling and Coaxial Output

Published coupling values range from 20 dB to 60 dB, with N-Type, SMA or 2.92 mm female outputs selected according to the model range.

04

Material, Flange and Finish Options

Aluminum or copper construction is available with cover and grooved flange combinations, Surtec corrosion protection and chromate or painted finishes.

Operating Principle

How a Waveguide Loop Coupler Is Used

A loop coupler transfers part of the energy in the main waveguide into a coaxial sampling port. Coupling controls the sample level; directivity describes separation of the wanted traveling wave from the opposite direction. A reduced sample still needs to be checked against the instrument’s average and peak input limits.

Forward-Power Monitoring

The coupling port can provide a reduced-level representation of transmitted power for system supervision, calibration, control loops or protection circuits.

  • Power-amplifier and transmitter monitoring.
  • Closed-loop process control.
  • Test and verification signal access.

Reflected-Power Monitoring

For reflected-power monitoring, specify the reverse-sampling orientation or a dual-directional arrangement. The published 12–15 dB directivity is not a measurement-accuracy figure; leakage from the opposite traveling wave contributes to the measured sample. Define the required directivity over the actual band before using the coupler for mismatch measurements.

  • Antenna or load mismatch detection.
  • Protection of sensitive RF sources.
  • Commissioning and maintenance diagnostics.
01

Select the WRD Band

Match both flanges to the adjoining double-ridged waveguide components. Use a WRD transition only where a change of port size is required and the operating bands overlap.

02

Define the Sample Level

Specify coupling from main-line power and instrument input limits, allowing for coupling tolerance, frequency response and any sampling-cable loss. Confirm CW and peak-power ratings for the coupler itself; they are not listed in this model table.

03

Confirm Direction and Interface

Specify forward, reverse or dual-direction sampling, along with coupling connector, flange arrangement and orientation.

Typical Uses

Applications

Double-ridge loop couplers provide reduced-level signal access for monitoring, measurement and protection functions in broadband RF and microwave systems.

  • Radar and Electronic SystemsSample forward or reflected RF power in radar transmitters, subsystem assemblies and electronic test platforms.
  • Satellite CommunicationsProvide monitoring points within broadband ground-station, antenna-feed, uplink and downlink equipment.
  • Broadband RF and Millimeter-Wave TestSupport characterization, calibration and signal monitoring across research, validation and production-test systems.
  • Industrial Microwave SystemsMonitor delivered and reflected power in heating, drying, plasma, materials-processing and process-control equipment.
Engineering Options

Customization & Support

Dolph Microwave can review custom coupling values, flange designs, connector arrangements, materials and finishes against the required operating band and system interface.

Coupling Configuration

Specify coupling level, tolerance, forward or reverse sampling direction, single or dual outputs and required directivity.

Mechanical Interface

Specify the WRD size, cover and grooved flange codes, connector orientation and mounting clearance. If sealing is required, include pressure, temperature and leak-test requirements; no pressure rating is provided in the model table.

Material and Finish

Define aluminum or copper construction, Surtec or chromate treatment, paint color, environmental exposure and flange-face requirements.

Standard Model Range

Double-Ridge Waveguide Loop Coupler Specifications

The original model rows, flange codes, coupling outputs, materials and finishes are retained below. DWG and STEP identify document types; request the current drawing for the selected model. Read the coupler selection guide for the distinction between coupling, directivity and sampling requirements.

Model Freq. Range
(GHz)
WG Size VSWR Coupling
(dB)
Directivity
(dB)
Coupling Output Flange Type Material Finish Datasheet
Cover Grooved DWG STEP
DH-840DRWHC30…0.84–2.0WRD8401.15:120–6012–15N-KFPWRD840U24FMWRD840U24Al/CuChromate/PaintedDWGSTEP
DH-150DRWHC30…1.5–3.6WRD1501.15:120–6012–15N-KFPWRD150D24FMWRD150D24Al/CuChromate/PaintedDWGSTEP
DH-200DRWHC30…2.0–4.8WRD2001.15:120–6012–15N-KFPWRD200D24FMWRD200D24Al/CuChromate/PaintedDWGSTEP
DH-250DRWHC30…2.6–7.8WRD2501.15:120–6012–15N-KFPWRD250D30FMWRD250D30Al/CuChromate/PaintedDWGSTEP
DH-350DRWHC30…3.5–8.2WRD3501.15:120–6012–15N-KFPWRD350D24FMWRD350D24Al/CuChromate/PaintedDWGSTEP
DH-475DRWHC30…4.75–11.0WRD4751.15:120–6012–15N-KFPWRD475D24FMWRD475D24Al/CuChromate/PaintedDWGSTEP
DH-500DRWHC30…5.0–18.0WRD5001.15:120–6012–15N-KFPWRD500D36FMWRD500D36Al/CuChromate/PaintedDWGSTEP
DH-580DRWHC30…5.8–16.0WRD5801.15:120–6012–15N-KFPWRD580D28FMWRD580D28Al/CuChromate/PaintedDWGSTEP
DH-650DRWHC30…6.5–18.0WRD6501.15:120–6012–15SMA-KFPWRD650D28FMWRD650D28Al/CuChromate/PaintedDWGSTEP
DH-700DRWHC30…7.0–18.5WRD7001.15:120–6012–15SMA-KFPWRD700D26FMWRD700D26Al/CuChromate/PaintedDWGSTEP
DH-750DRWHC30…7.5–18.0WRD7501.15:120–6012–15SMA-KFPWRD750D24FMWRD750D24Al/CuChromate/PaintedDWGSTEP
DH-110DRWHC30…11.0–26.5WRD1101.15:120–6012–152.92-KFPWRD110C24FMWRD110C24Al/CuChromate/PaintedDWGSTEP
DH-180DRWHC30…18.0–40.0WRD1801.15:120–6012–152.92-KFPWRD180C24FMWRD180C24Al/CuChromate/PaintedDWGSTEP
Selection note: The coupling and directivity values shown are product-family data. Confirm coupling tolerance, full-band directivity, insertion loss, power handling and test conditions in the model-specific quotation or approved datasheet.
Ordering Logic

Part Number Guide

The example below shows how waveguide size, directionality, coupling, connector, flange and material are encoded. Confirm the final code in the approved quotation.

DH-840DRWHC30NKPMA
  • 840DRWaveguide size: WRD840
  • WHCSingle directional loop coupler
  • WDHCDual directional loop coupler
  • 30Coupling: 30 dB
  • NCoupling connector: N-Type
  • KInterface type: Female
  • PFlange type: Rectangular flat
  • MFlange type: Rectangular grooved
  • A / CMaterial: Aluminum / Copper
Surface Protection

Finish and Corrosion-Protection Note

All Dolph-MW models include a Surtec/corrosion-protection treatment and are painted flat black. Flanges are unplated, polished and Surtec treated. Other finishes and paint colors are available upon request.

Specification-Based Quotation

Information to Include in a Coupler RFQ

Complete inputs are required to verify the coupling port, waveguide interfaces, sampling direction and performance across the intended operating band.

Request Technical Review
  • Frequency RangeMinimum and maximum operating frequencies, including any restricted sub-bands.
  • Waveguide SizeRequired WRD series and mating component details.
  • Coupling ValueNominal dB value, acceptable tolerance and frequency flatness.
  • DirectionalitySingle or dual directional arrangement and required sampling orientation.
  • Main-Line PowerAverage power, peak power, duty cycle and pulse conditions.
  • Coaxial OutputN-Type, SMA, 2.92 mm or another interface, including gender and orientation.
  • Flange ArrangementCover/grooved combination, flange codes, clocking and mounting constraints.
  • EnvironmentTemperature, corrosion exposure, vibration, sealing requirements, finish and documentation.
Technical Documents

Downloads

The flange document provides interface terminology. The high-power termination PDF is a related load reference, not a datasheet or power-rating source for this coupler. Request a model-specific drawing and RF data with the quotation.

Scroll to Top
Blank Form (#3)