Broadband WRD Coverage
The listed WRD models cover different bands between 0.84 and 40 GHz. Match the complete operating band to the selected row, not just its upper frequency.
HOME » Waveguide, RF & Microwave Components » Double-Ridged Waveguide Loop Couplers
Double-ridged waveguide loop couplers provide coaxial RF samples for power monitoring and test access. Published models cover individual bands within 0.84–40 GHz, with 20–60 dB coupling options, 1.15:1 VSWR and 12–15 dB directivity. Specify the WRD interface, sampling direction, main-line power and instrument input limits.
Dolph Microwave double-ridged waveguide loop couplers extract a reduced-level RF sample from a WRD waveguide path for power monitoring, system adjustment and test access. The model table lists 13 configurations with individual bands within 0.84–40 GHz, coupling options of 20–60 dB, VSWR of 1.15:1 and directivity of 12–15 dB. Select a complete model row; no single coupler spans the entire family range.
Choose the waveguide band and sampling direction before specifying the coupling level. DH-840DRWHC30… uses WRD840 over 0.84–2.0 GHz with an N-K output; DH-180DRWHC30… uses WRD180 over 18.0–40.0 GHz with a 2.92-K output. The ordering guide defines K as female. The output connector must match the instrument or sampling cable, as well as the required operating band.
The listed WRD models cover different bands between 0.84 and 40 GHz. Match the complete operating band to the selected row, not just its upper frequency.
Single-directional and dual-directional formats support forward-power, reflected-power or two-direction monitoring.
Published coupling values range from 20 dB to 60 dB, with N-Type, SMA or 2.92 mm female outputs selected according to the model range.
Aluminum or copper construction is available with cover and grooved flange combinations, Surtec corrosion protection and chromate or painted finishes.
A loop coupler transfers part of the energy in the main waveguide into a coaxial sampling port. Coupling controls the sample level; directivity describes separation of the wanted traveling wave from the opposite direction. A reduced sample still needs to be checked against the instrument’s average and peak input limits.
The coupling port can provide a reduced-level representation of transmitted power for system supervision, calibration, control loops or protection circuits.
For reflected-power monitoring, specify the reverse-sampling orientation or a dual-directional arrangement. The published 12–15 dB directivity is not a measurement-accuracy figure; leakage from the opposite traveling wave contributes to the measured sample. Define the required directivity over the actual band before using the coupler for mismatch measurements.
Match both flanges to the adjoining double-ridged waveguide components. Use a WRD transition only where a change of port size is required and the operating bands overlap.
Specify coupling from main-line power and instrument input limits, allowing for coupling tolerance, frequency response and any sampling-cable loss. Confirm CW and peak-power ratings for the coupler itself; they are not listed in this model table.
Specify forward, reverse or dual-direction sampling, along with coupling connector, flange arrangement and orientation.
Double-ridge loop couplers provide reduced-level signal access for monitoring, measurement and protection functions in broadband RF and microwave systems.
Dolph Microwave can review custom coupling values, flange designs, connector arrangements, materials and finishes against the required operating band and system interface.
Specify coupling level, tolerance, forward or reverse sampling direction, single or dual outputs and required directivity.
Specify the WRD size, cover and grooved flange codes, connector orientation and mounting clearance. If sealing is required, include pressure, temperature and leak-test requirements; no pressure rating is provided in the model table.
Define aluminum or copper construction, Surtec or chromate treatment, paint color, environmental exposure and flange-face requirements.
The original model rows, flange codes, coupling outputs, materials and finishes are retained below. DWG and STEP identify document types; request the current drawing for the selected model. Read the coupler selection guide for the distinction between coupling, directivity and sampling requirements.
| Model | Freq. Range (GHz) |
WG Size | VSWR | Coupling (dB) |
Directivity (dB) |
Coupling Output | Flange Type | Material | Finish | Datasheet | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cover | Grooved | DWG | STEP | |||||||||
| DH-840DRWHC30… | 0.84–2.0 | WRD840 | 1.15:1 | 20–60 | 12–15 | N-K | FPWRD840U24 | FMWRD840U24 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-150DRWHC30… | 1.5–3.6 | WRD150 | 1.15:1 | 20–60 | 12–15 | N-K | FPWRD150D24 | FMWRD150D24 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-200DRWHC30… | 2.0–4.8 | WRD200 | 1.15:1 | 20–60 | 12–15 | N-K | FPWRD200D24 | FMWRD200D24 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-250DRWHC30… | 2.6–7.8 | WRD250 | 1.15:1 | 20–60 | 12–15 | N-K | FPWRD250D30 | FMWRD250D30 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-350DRWHC30… | 3.5–8.2 | WRD350 | 1.15:1 | 20–60 | 12–15 | N-K | FPWRD350D24 | FMWRD350D24 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-475DRWHC30… | 4.75–11.0 | WRD475 | 1.15:1 | 20–60 | 12–15 | N-K | FPWRD475D24 | FMWRD475D24 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-500DRWHC30… | 5.0–18.0 | WRD500 | 1.15:1 | 20–60 | 12–15 | N-K | FPWRD500D36 | FMWRD500D36 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-580DRWHC30… | 5.8–16.0 | WRD580 | 1.15:1 | 20–60 | 12–15 | N-K | FPWRD580D28 | FMWRD580D28 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-650DRWHC30… | 6.5–18.0 | WRD650 | 1.15:1 | 20–60 | 12–15 | SMA-K | FPWRD650D28 | FMWRD650D28 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-700DRWHC30… | 7.0–18.5 | WRD700 | 1.15:1 | 20–60 | 12–15 | SMA-K | FPWRD700D26 | FMWRD700D26 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-750DRWHC30… | 7.5–18.0 | WRD750 | 1.15:1 | 20–60 | 12–15 | SMA-K | FPWRD750D24 | FMWRD750D24 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-110DRWHC30… | 11.0–26.5 | WRD110 | 1.15:1 | 20–60 | 12–15 | 2.92-K | FPWRD110C24 | FMWRD110C24 | Al/Cu | Chromate/Painted | DWG | STEP |
| DH-180DRWHC30… | 18.0–40.0 | WRD180 | 1.15:1 | 20–60 | 12–15 | 2.92-K | FPWRD180C24 | FMWRD180C24 | Al/Cu | Chromate/Painted | DWG | STEP |
The example below shows how waveguide size, directionality, coupling, connector, flange and material are encoded. Confirm the final code in the approved quotation.
DH-840DRWHC30NKPMAAll Dolph-MW models include a Surtec/corrosion-protection treatment and are painted flat black. Flanges are unplated, polished and Surtec treated. Other finishes and paint colors are available upon request.
Complete inputs are required to verify the coupling port, waveguide interfaces, sampling direction and performance across the intended operating band.
Request Technical ReviewThe flange document provides interface terminology. The high-power termination PDF is a related load reference, not a datasheet or power-rating source for this coupler. Request a model-specific drawing and RF data with the quotation.