Yes. Dolph Microwave supplies custom waveguide assemblies with end flanges, fully brazed and tested before shipment. If your drawing calls for welding rather than brazing, confirm the joining process before ordering. For a catalogue bend, ask the supplier to confirm the flange configuration, whether each unit will be RF-tested, and what measured data will ship with it.
If the bend must bolt between two fixed ports, show both mating faces on the drawing. Mark the direction each flange faces and which end mates to which port. Use that same drawing to agree on what will arrive as one assembly and what, such as gaskets or mounting hardware, must be quoted separately.

Table of Contents
Standard miter bends
The miter bend catalogue spans 0.32 to 40 GHz across WR2300 through WR28. E-plane models use the WTEB code and H-plane models use WTHB. The H-plane entries are labelled “20%”; confirm the required sweep rather than assuming the listed frequency range is the test band.
| Model | Listed frequency range | VSWR | Insertion loss | Flanges | A × B |
|---|---|---|---|---|---|
| DH-100 E-plane, WR90 | 8.20–12.40 GHz | 1.1:1 | 0.2 dB | UDR100/UBR100 cover, PDR100/PBR100 grooved | 25 × 25 mm |
| DH-100 H-plane, WR90 | 8.20–12.4 GHz | 1.1:1 | 0.2 dB | UDR100/UBR100 cover, PDR100/PBR100 grooved | 30 × 30 mm |
| DH-320 E-plane, WR28 | 26.5–40.0 GHz | 1.1:1 | 0.25 dB | UBR320 cover, PBR320 grooved | 12 × 12 mm |
| DH-320 H-plane, WR28 | 26.5–40.0 GHz | 1.1:1 | 0.25 dB | UBR320 cover, PBR320 grooved | 18 × 18 mm |
| DH-3 E-plane, WR2300 | 0.32–0.49 GHz | 1.15:1 | 0.15 dB | UDR3 cover, PDR3 grooved | 220 × 220 mm |
On a tight WR28 installation, the two DH-320 rows can look interchangeable: the flange codes and listed RF values match, but the E-plane and H-plane leg dimensions are 12 × 12 mm and 18 × 18 mm, respectively. Check the bend plane and flange locations on the approved drawing before releasing the order.
Double-ridged bends
The double-ridged bend catalogue spans WRD840 to WRD180, with individual model bands within 0.84 to 40.0 GHz. Listed VSWR is 1.20:1 or 1.25:1, depending on the model. The loss column is labelled dB/m; do not use it as a per-bend insertion-loss limit without confirming the measurement definition and reference planes.
For a 24–26 GHz system with WRD180 ports, the WRD180 row lists 18.0–40.0 GHz, so it covers the band on paper. If 24–26 GHz is the full operating band, specify that sweep in the order and ask for the loss of the finished bend in dB between the agreed measurement planes.
If the project requires documentation under the RoHS Directive [1] or the REACH regulation [2], request the applicable declarations for the ordered part and finish.
Custom pre-welded assemblies
The miter bend catalogue lists 90° as standard and 30°, 45° and 60° on request. For a route that combines E- and H-plane bends, waveguide twists or straight waveguide sections, send a drawing of the full assembly. Dolph lists oxygen-free copper for its custom assemblies. Its multi-bend line spans 1.72 to 110 GHz across WR-10 to WR-430, with VSWR listed as low as 1.06:1. That is a catalogue figure, not a limit for every build.
What to send for a quote
- WR or WRD size, operating band, bend plane and angle. If power matters, specify whether operation is continuous or pulsed and give the applicable power levels. Ask what rating can be confirmed for the exact build; do not infer it from catalogue VSWR.
- Flange code at each end and any gasket or sealing requirements. Use the EIA and IEC flange cross-reference to identify codes, then check the bolt pattern, aperture and flange face against the mating equipment.
- Leg dimensions, drawing revision, body material and finish. State any required joining process on the drawing.
- RF acceptance criteria: sweep band, port configuration, maximum insertion loss, and either maximum VSWR or minimum return loss. Specify whether you need per-unit testing and serial-numbered reports, and agree on the documents before placing the purchase order. See Dolph’s manufacturing and inspection guidance.
For a sealed assembly, specify pressure or leak testing separately. Give the required test conditions and acceptance limit, and ask for the result in the order documentation. An RF report is not evidence that the assembly meets a leak requirement.
How to set an RF acceptance limit
VSWR and return loss describe reflection at a port. Insertion loss is a separate check on how much signal gets through. A maximum VSWR of 1.1:1 corresponds to a minimum return loss of about 26.4 dB at the same port and frequency, using −20 log10((VSWR − 1)/(VSWR + 1)). That is a calculated equivalent, not a test result. In the purchase order, state which reflection limit applies, which port or ports to check, and the separate insertion-loss limit.
What to check on delivery
Inspect the flange faces and match the part number and drawing revision to the order. If you requested per-unit reports, match each serial number to its report and check that the measured sweep covers your operating band. If your order requires ISO 9001 certification, request the supplier’s current certificate and check its scope; the standard covers quality management systems, not the RF performance of a particular bend [3].
For example, suppose a WR28 purchase order sets a maximum insertion loss of 0.25 dB over 28–32 GHz. If the unit’s report shows 0.30 dB at 31 GHz, the unit does not meet that limit even if its VSWR passes. If the report stops at 30 GHz, it does not establish compliance over the full band. Ask for a complete report before accepting the unit.
Send your drawing or catalogue model number with the required RF test scope.