
Yes, you can request a custom waveguide assembly with a 3° bend. Ask the supplier to confirm feasibility for your size, band, and layout. First clarify what 3° means: does the outlet need to point 3° away from the inlet, or do the ports need to stay parallel with a sideways offset? A dimensioned sketch showing both port centerlines and flange faces is enough to start that discussion.
If 3° came from a routing sketch rather than a mating requirement, say so. For fixed parallel ports, give the supplier the measured lateral offset and the available space, and say whether the bend angle can change. If the outlet itself must point 3° off-axis, mark that orientation and the direction of tilt instead.
Table of Contents
Catalog bends versus custom assemblies
| Option | Angle | Published size and band coverage | Published RF specifications |
|---|---|---|---|
| Catalog miter bends | 90° standard; 30°, 45°, and 60° by special order | WR2300–WR28, 0.32–40 GHz, 48 models | VSWR 1.10:1–1.15:1; insertion loss 0.15–0.25 dB, depending on model |
| Custom multi-bend | Ask about 3° for your layout | WR-10–WR-430, 1.72–110 GHz | VSWR as low as 1.06:1 for the family |
| Hybrid rigid-flexible | Ask about 3° for your layout | WR-10–WR-650, 1.13–110 GHz | Agree on limits for the proposed assembly |
These ranges span product families. They do not describe a single part or guarantee the RF performance of a 3° build. For the catalog option, check the row for your exact model.
How to dimension a 3° offset
A single 3° bend changes the direction of the outlet. If the ports must stay parallel, a second bend of 3° in the opposite direction and in the same plane brings the outlet axis back parallel. In the idealized layout below, L is the centerline distance along the angled section between the two bend vertices, not the overall flange-to-flange length.
| Angled centerline length (L) | Ideal lateral offset (L × sin 3°) |
|---|---|
| 50 mm | ≈ 2.6 mm |
| 100 mm | ≈ 5.2 mm |
| 150 mm | ≈ 7.9 mm |
| 200 mm | ≈ 10.5 mm |
For example, if the mating ports are parallel and 5.2 mm apart sideways, a 100 mm angled run at 3° gives about 5.2 mm in the ideal layout. If your sketch labels 100 mm from flange face to flange face instead, that is not L. Dimension the required offset between port centerlines at the mating faces and have the supplier check the available space with the actual bend radii and flange geometry.
Run the calculation backward when space is tight. For a 10 mm lateral move at 3°, the ideal angled segment alone is 10 mm ÷ sin 3°, or about 191 mm. Its projection along the inlet axis is about 190.8 mm, before allowing for straight ends and flanges in the ideal layout. If your flange faces are only 100 mm apart along that axis, the proposed two-bend layout will not fit as drawn. Ask whether a larger bend angle or a different route can meet the same port positions instead of asking the shop to shorten the 3° run.
Put separate tolerances on the bend angle and the lateral offset. If the ports must stay parallel, specify the allowed flange-face angle separately. A bend-angle tolerance such as 3° ± 0.25° is an example, not a default; use what the installation and RF requirements allow.
When to use a rigid or flexible assembly
If both ports are fixed, start with a rigid build sized to the mating interfaces. Dolph Microwave lists oxygen-free copper, fully brazed construction, and testing for its custom assemblies. Ask whether a formed or fabricated bend fits your envelope and RF limits.
If the installation needs to accommodate movement or misalignment, ask whether a hybrid assembly or a flexible waveguide section can take up the displacement. Confirm the permitted bend radius, whether service is static or repeatedly flexing, and the RF limits for the exact configuration. Do not assume a preformed section can be flexed repeatedly in service.
For a fixed replacement, send the installed port positions, not just a photo of the old part. If one port moves during operation, give the supplier its positions at both ends of travel and any intermediate position with less clearance. Ask which installed shape the RF limits apply to and whether any other positions need to be tested.
What a small offset does to RF performance
The bend angle alone does not tell you how much power will be reflected or transmitted. A 90° H-plane modeling example hosted by the University of Vaasa explains why a smooth curve with a sufficiently large radius can reduce reflection [1]. An NRAO note on right-angle miter bends shows why junction dimensions and operating frequency matter to the match [2]. Neither source supplies a loss value for your 3° assembly.
IEEE 1785.1 covers rectangular metallic waveguides at 110 GHz and above, including how aperture tolerances affect reflection and attenuation [3]. An NPL/NIST review explains the tolerance grades and their worst-case reflection figures [4]. Those grades do not set the flange or bend tolerances of a lower-frequency custom assembly.
For specific optimized right-angle bend geometries, Lee, Bang, and Ahn reported simulated reflection below −35 dB from 1.1 to 1.9 times the dominant TE10 mode cutoff frequency [5]. Treat that as a result for those designs, not an acceptance limit for a 3° offset. If you receive a simulation with a quote, check that it covers your full band and represents the proposed assembly, then agree separately on what the supplier will measure on the finished part.
What to put on your drawing
IEC 60153-2:2025 covers straight tubing for ordinary rectangular metallic waveguides and leaves material selection to the buyer and supplier [6]. Use the applicable size designation, then define the finished assembly on your drawing and in the RF test requirements.
| Item | What to specify |
|---|---|
| Waveguide and band | Size designation (WR or IEC R-series) and the full operating frequency range |
| Bend and port positions | E-plane or H-plane; bend direction; angle and offset with separate tolerances; required outlet orientation |
| Installation envelope | Straight lengths, overall clearance, and room for fasteners and any waveguide-to-coax test adapters |
| Flanges | Interface type, face location, and bolt-hole orientation at each end |
| Materials and environment | Base metal, plating, temperature, vibration, and any sealing or pressurization requirements |
| RF acceptance | Maximum VSWR or minimum return loss, maximum insertion loss, and where the measurements are referenced |
What to check before approving the drawing
- Check the offset direction from a stated view. Label the inlet and outlet and show which way the outlet moves when viewed from the inlet. If you are unsure whether to call it an E-plane or H-plane bend, show the wide and narrow walls of the rectangular opening on the end view and ask the supplier to confirm the plane.
- Check the two flange faces independently. On a parallel-port assembly, the centerlines can land in the right locations while the outlet bolt pattern is rotated incorrectly. Compare both end views with the mating hardware and check that there is room to tighten the fasteners.
- Compare quotes against the same drawing revision. Ask which dimensions will be inspected on the finished assembly, whether swept RF data are included, and whether the report will identify the delivered unit. A catalog trace or a simulation may help evaluate the design, but it is not an acceptance report for the unit you receive.
What to confirm for high-power service
Give the supplier the peak and average power, gas and pressure conditions, cooling, and ambient temperature. In its multipactor handbook for space RF hardware, ECSS explains that downstream mismatch can increase the peak field in an upstream component [7]. Ask for a rating for your actual setup rather than inferring one from the bend angle or catalog VSWR.
What to ask for in the RF test report
Ask for both a reflection sweep (VSWR or return loss) and an insertion-loss sweep across your operating band. The first shows how well the assembly is matched; the second shows how much signal is lost in transmission through it. A good VSWR alone does not establish low insertion loss.
If one spec uses VSWR and the other uses return loss, compare them in the same units. NBS Technical Note 619, archived by NIST, gives the relation |Γ| = (VSWR − 1)/(VSWR + 1) [8]. With return loss defined as −20 log10|Γ|, 1.06:1, 1.10:1, and 1.15:1 convert to about 30.7, 26.4, and 23.1 dB, respectively. Those are conversions of published values, not measurements of the offset assembly.
For example, suppose your purchase specification requires at least 25 dB of return loss across the operating band. A reported 1.10:1 at one frequency meets that limit at that point, but a rise to 1.15:1 anywhere else in the band fails it there. Check the highest VSWR or lowest return loss across the band, then check the highest insertion loss against its own limit. The 25 dB threshold is for illustration, not a recommended specification.
Before comparing the plots with your limits, check where the measurement starts and ends. If your limits are for the assembly between its flange faces, ask the supplier to state whether the plots are referenced to those faces or include the test adapters. If either end can serve as the input, agree on which ports need reflection data before the order is placed.
Request a quote for a 3° waveguide assembly
Send your sketch, waveguide size, flange details, and operating band. Ask the supplier to confirm the proposed geometry and agree on the RF test limits before fabrication.
Get a Quote