Flange bolt holes miss when the two flanges have different drilling patterns, one flange is rotated relative to the other, or the parts sit out of position even though the drawings agree. If the holes line up but the faces will not seat, check for debris, a seal problem, or interference at a locating pin before blaming the drilling. Compare both approved drawings first, then check how the flanges sit on their supports without pulling them together with bolts.
Before loosening or handling a joint on equipment that has been in service, follow the site’s isolation and line-opening procedures. Do not start hands-on checks until the equipment is verified safe for the work, including control of trapped pressure and other hazardous stored energy. In covered U.S. general-industry servicing, hazardous-energy control is addressed in 29 CFR 1910.147 [1].
Table of Contents
Different Flange Standards or Drilling Patterns
Matching outside diameters do not establish compatibility. On pipe flanges, compare the full designations, governing standards, nominal sizes, pressure class or rating as applicable, and facing. Use the approved drawing revisions to compare the bolt count, bolt-circle diameter, and hole diameter. For a square or rectangular flange, compare hole-center coordinates from the specified drawing reference points, or datums. Check whether each corresponding hole is meant to be threaded or clear. An eight-hole flange cannot match a twelve-hole flange hole for hole, even if an individual pair happens to overlap.
Drilling example: Suppose two eight-hole flanges on a bench have measured bolt-circle diameters of 150 mm and 154 mm, and each pattern is centered on its own flange. With the flanges centered and the hole angles matched, the holes on the larger circle sit 2 mm farther out all the way around. Rotation cannot change that radial difference. Compare each part with its own approved drawing to find out whether a part is wrong or the specified interfaces differ. These dimensions are illustrative; 2 mm is not an allowable offset.
If the hole centers line up but a fastener will not start in a tapped hole, check the specified thread diameter and pitch, the fastener, and the condition of the first threads. If it starts but stops before the parts seat, also check the specified fastener length and available depth in any blind hole. That symptom alone does not justify rotating the flange or enlarging a hole.
Flanges Rotated Out of Position
Clocking is the angular position of the hole pattern relative to a reference on the drawing. Compare the reference marks and hole positions using the same viewing direction; photos taken looking at opposite mating faces can make left and right appear reversed. On two identical, evenly spaced bolt circles with coincident centers and parallel faces, a pure rotation shifts corresponding hole centers by equal distances but in different directions around the circle. If several holes miss mainly in the same sideways direction, check for displaced centers rather than assuming a half-pitch rotation. If the offset varies around the circle, check for a combination of rotation, displacement, tilt, or a different drilling pattern.
Illustrative fit-up: Suppose both flanges have the same eight-hole circle specified on the drawings. The hole spacing is 360° ÷ 8 = 45°, so half a pitch is 22.5°. If the faces are parallel and centered and all the hole centers show that angular offset, the measurements point to clocking. If a loose pin passes through one pair, that only shows local clearance; it does not establish the angle or prove that the remaining holes are correct. Record the discrepancy against the drawing datum instead of trying to turn a fixed spool.
Pipe Strain or Incorrect Support Position
When the drilling and clocking match the drawings, check whether the installed flange centers coincide and the faces are parallel in the specified fit-up condition. A gap wider on one side points to a face-angle problem or an obstruction; a sideways offset with parallel faces points you toward the support elevation or spool position. Look for a misplaced support, an incorrect spool length, or weld distortion. Record whether the check was made in the specified cold fit-up condition, since operating temperature can change where a pipe run sits.
Do not use the bolts to pull a visibly misaligned joint into position. Report where the flange sits on its approved supports and where the gap is widest. For waveguide runs, Dolph’s flexible waveguide installation guidance likewise calls for supports and hangers that carry the run without loading the flexible section at a flange.
Gap example: With the joint safe to inspect and resting on its approved supports, record the gap at accessible points around the perimeter using one marked viewing direction. Suppose the gap is 3 mm at the top and 1 mm at the bottom. That difference warrants a check for nonparallel faces or local interference, not a bolt-pattern change. If the gap is even but several holes miss downward, record the direction of the center offset and check support elevation or spool position. Neither set of observations, by itself, identifies which part moved or how to correct it.
Fabrication and Measurement Errors
Compare like with like: bolt-circle diameter is measured through the hole centers, not to their edges or to the flange rim. Check whether the drawing dimensions apply before or after coating. Burrs, weld spatter, or leftover gasket material may hold the faces apart without changing the hole coordinates. If the parts pass their individual checks but still will not fit, have engineering compare the two sets of measurements against the assembly requirements rather than treating either part as defective on that evidence alone.
For an even, circular pattern with genuinely opposite holes, measure across the centers of more than one opposite pair as a cross-check. If the readings disagree, record the pairs and use the inspection method specified for the part instead of averaging away the difference. For a rectangular pattern, record both coordinates from the drawing datums; a single diagonal cannot confirm every hole position.
One inch is exactly 25.4 mm; NIST gives the inch-to-metre factor as 2.54 × 10−2 [2]. If 1/2 in is copied as 12 mm instead of 12.7 mm, the record is off by 0.7 mm. Whether that matters to fit depends on the drawing tolerance and available clearance. Keep the original dimension and tolerance in the record and convert both together.
Waveguide Bolts Fit but the Faces Do Not Seat
Compare the aperture dimensions and orientation, locating pins and their mating holes, specified face pairing, and seal arrangement. A pin with no matching hole or a seal not specified for the interface can prevent seating even when the bolt pattern agrees. Do not assume that the two faces must look identical; the approved mating drawing determines which face types are intended to work together.
Dolph’s EIA and IEC waveguide flange reference lists WR90 at 8.2–12.5 GHz and WR75 at 9.84–15 GHz. Those overlapping manufacturer-listed bands help identify the waveguide sizes; they are not evidence of flange interchangeability. If a waveguide pressure window is involved, verify the flange on the side that actually mates with the assembly.
Replacement window example: Suppose the waveguide size and bolt pattern match, but a locating pin stops against the new window flange. Mark the mating side on the drawing and check whether its pin and receiving-hole positions agree in the installed orientation. If the pins clear but the face still stands off, compare the specified seal and groove before assuming the window has the wrong drilling. Confirm the face pairing with the supplier before substituting a part; do not omit the seal or remove a pin to make it fit.
Mechanical fit is not an RF acceptance test. In a worked example at the same measurement reference plane, a VSWR of 1.20 corresponds to about 0.83% reflected power (20.83 dB return loss); 1.50 corresponds to 4.00% (13.98 dB). These figures illustrate reflection, not flange ratings or acceptance limits. A higher reading at the same frequency and reference plane means more reflection, but it does not tell you which part caused it. Compare the result with the limit in the test plan. If a waveguide-to-coaxial adapter is part of the test setup, record the reference plane before attributing a measured mismatch to one joint.
On-Site Flange Alignment Checklist
- Once the joint is safe to inspect, identify both parts and match their markings to the current approved drawings.
- Compare the bolt patterns, hole types, and orientation using the drawing datums.
- Check center offset, face gap, and seating in the approved support condition. Note whether a pin, gasket, or surface obstruction prevents full seating.
- Record both part numbers, flange codes, drawing revisions, measurements and units, measurement tools, and fit-up temperature. Photograph both faces with visible identification and orientation marks.
| What you see | What it may indicate | What to check first |
|---|---|---|
| The hole counts or bolt-circle diameters differ | Different drilling patterns | Part markings and approved drawings for both sides |
| Matching centered circles have a uniform angular offset | Incorrect clocking | Hole angles from the same orientation datum |
| Several holes miss toward the same side | Center offset | Flange centerlines and support positions |
| One side of the face gap is wider | Nonparallel faces or an obstruction | Gap around the perimeter and condition of both faces |
| The holes align, but a bolt will not start or seat | Thread, fastener length, or blind-hole depth issue | Specified fastener and mating thread; check available depth if the bolt starts and then stops |
| Waveguide bolt holes line up, but the faces will not seat | Locating-pin, face, or seal interference | Pin and seal locations against the mating drawing |
When to Stop the Fit-Up
Stop and refer the joint to the responsible engineer if a pressure-retaining or load-bearing interface cannot be identified, the faces are damaged, the flange has been modified without approval, or the joint only lines up under force. Do not enlarge or slot bolt holes, remove locating features, or heat or cut parts as a site fix. A fit-up check does not approve an altered joint for service.
What to Send Before Rework or Reordering
- Part or drawing mismatch: Give quality or purchasing both markings and drawing revisions, and state which measured feature differs. Ask for the approved replacement interface, not just the same nominal size.
- Parts match but the installation does not: Give the responsible engineer the direction of the offset, face gaps by position, and the support condition. Do not specify a support adjustment based on the hole pattern alone.
- After an approved correction: Repeat the measurements from the same datums in the specified fit-up condition and record the result before the job proceeds to its required assembly and acceptance checks.
For the next replacement, confirm the mating drawing before ordering and check the incoming part against it while the hole pattern, threads, and locating features are still accessible.
Need to confirm a waveguide mating interface?
Send both flange codes, the approved drawing revision, and marked photos of both mating faces.